TitleAssessment of core status of TEPCO's Fukushima Daiichi Nuclear Power Plants 89 - Review on station blackout caused by tsunami in Fukushima Daiichi NPS
Alternative title東京電力福島第一原子力発電所炉内状況把握の解析・評価 89 - 福島第一原子力発電所の津波による非常用交流電源喪失についての再検証
AuthorYamauchi, Daisuke(Tokyo Electric Power Co. Holdings, Inc.)
AuthorDate, Kenji(Tokyo Electric Power Co. Holdings, Inc.)
AuthorEndo, Ryouhei(Tokyo Electric Power Co. Holdings, Inc.)
AuthorMizokami, Masato(Tokyo Electric Power Co. Holdings, Inc.)
AuthorHonda, Takeshi(Tokyo Electric Power Co. Holdings, Inc.)
AuthorNozaki, Kenichiro(Tokyo Electric Power Co. Holdings, Inc.)
AuthorMizokami, Shinya(Tokyo Electric Power Co. Holdings, Inc.)
Issued date2017-03-28
Languagejpn
Pagep.2K15
Typeproceedings
File FormatTEXT (paper-based)
Taxonomy4-6-1 Reconstruction
Taxonomy2-1-1-4-7 Tsunami
Taxonomy2-2-9 Power supply
Taxonomy(Computer Assigned)4-6 Emergency and response analysis   2-1-1-4 Water reservoirs and flooding   2-2 Design   
Subject/Session_nameSession:Thermal Hydraulics, Energy Conversion, Energy Transfer, Energy Storage