TitleTrial calculation of the storage capacity of the intermediate storage facility using Pneumatic Caisson Method based on nuclear fuel debris storage can size of the Fukushima Daiichi Nuclear Power Plant
Alternative title福島第一原子力発電所の燃料デブリの収納缶寸法に基づくニューマチックケーソンによる中間保管施設の保管可能容量の試算
AuthorSuzuki, Tadakatsu(Oriental Shiraishi Corp.)
AuthorAbe, Shintaro(Oriental Shiraishi Corp.)
AuthorHomma, Miko(Oriental Shiraishi Corp.)
AuthorKomine, Hideo(Waseda Univ.)
AuthorGoto, Shigeru(Waseda Univ.)
Issued date2020-09-09
Languagejpn
Pagep.CS11-26
Typeproceedings
File FormatPDF
Taxonomy5-3-1 Solid waste
Taxonomy3-2-6 Long term safe condition
Taxonomy5-5-4 Decommissioning planning
Taxonomy(Computer Assigned)5-3 Waste management   3-2 Accident management implementation   5-5 Decommissioning   
Information sourceGo to external webpageRelation URL
Meeting titleJapan Society of Civil Engineers 2020 Annual Meeting